Slot: tap_c
Phase C tap position, in steps (0.0 = neutral).
URI: distopf:tap_c
Applicable Classes
| Name |
Description |
Modifies Slot |
| RegulatorRecord |
Step voltage regulator data record for DistOPF |
no |
Properties
Type and Range
Cardinality and Requirements
| Property |
Value |
| ### Slot Characteristics |
|
- Not used on import (only tap_a is read; see the tap_a comment). Export: tap_c = step − neutralStep when the tap changer's phase resolves to C, following the same logic as tap_a.
TODOs
- Import does not read tap_c — a per-phase RatioTapChanger for phase C is never created from this field.
Annotations
| property |
value |
| order |
8 |
| value_type |
float |
| precision |
6 |
| separator |
|
Schema Source
- from schema: https://gridappsd.org/cimhub/distopf
Mappings
| Mapping Type |
Mapped Value |
| self |
distopf:tap_c |
| native |
distopf:tap_c |
LinkML Source
name: tap_c
annotations:
order:
tag: order
value: 8
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
separator:
tag: separator
value: ''
description: Phase C tap position, in steps (0.0 = neutral).
todos:
- Import does not read tap_c — a per-phase RatioTapChanger for phase C is never created
from this field.
comments:
- 'Not used on import (only tap_a is read; see the tap_a comment). Export: tap_c =
step − neutralStep when the tap changer''s phase resolves to C, following the same
logic as tap_a.'
from_schema: https://gridappsd.org/cimhub/distopf
rank: 1000
ifabsent: float(0.0)
owner: RegulatorRecord
domain_of:
- RegulatorRecord
range: float
required: false